The ultrasonic thickness gauge is the thickness testing equipment that can measure the thickness of various materials such as metal materials, high temperature pipes, pipes, steel plates, aluminum plates, plastics, iron pipes, PVC pipes, glass, etc. It can be widely applied for these material testing in the fields like manufacturing, metal processing, chemical industry, commodity inspection, etc. This series of ultrasonic thickness gauge is extremely suitable for measuring the thickness loss of pipes and pressure vessels after corrosion. The ultrasonic thickness gauge is a most suitable instrument for material protection.
With competitive price and timely delivery, Eastloong sincerely hope to be your supplier and partner.
Features
- 0.1mm or 0.001 inches resolution
- Measuring range: 0.8~300mm
- 128*64 pixels display with backlit
- Can store 500 thickness readings
- Hi-Low alarm setting
- Minimum thickness capture
- V-sound path correction
- With through paint/coating function (ATO-UM-1D only)
Specification
Model ATO-UM-1 ATO-UM-1D Display Type 128 ×64 dot-matrix LCD screen with EL backlight Operating Principle P-E (pulse-echo) with dual-crystal probe P-E (pulse-echo), E-E (Echo-Echo) with dual-crystal probe Total Measuring Range 0.8mm-300mm, depending on material and probe Measuring Range in Standard Mode Standard Probe PT-08: 0.8mm-100mmMeasuring Range in Thru Coating Mode N/A 3-20mm with PT-08 probe Measuring Limits of Tube (Steel) Φ20mm×3.0mm (PT-08 probe)
The measuring error is up to ± 0.1mm. Measuring Error Lower limit to 10mm: ±0.1mm
10mm to upper limit: ±(1%H+0.1)mm
Note: H is the actual thickness of the tested material Repeatability 0.1mm Display Resolution 0.1mm or 0.001 inch Units Inch or Millimeter Calibration Method Zero calibration, Two-point calibration V-Path Correction Automatic Update Rate 4Hz Material Velocity Range ~m/s (0. to 0.in/μs) Memory Function 5 arrays are divided to store 500 thickness values Minimum Value Checking Taking the probe to move along the surface of the tested material, the gauge is able to find the thinnest point automatically. Warning Function If the measured value exceeds the pre-set thickness limit, the guage will sound an alarm. Velocity Storage Can store 5 different materials' velocities in total Languages English and Chinese Communication Port (Optional) USB port or Serial RS 232 port Application Software (Optional) UmView Software for data transmission, storage, analysis and document editing Power Supply Two 1.5V AA alkaline batteries (Alarm for low battery voltage) Operating Time Up to 200 hours with alkaline batteries (without backlight) Instrument Shut-off AUTO OFF after 5 minutes of no operation Operating Temperature -10℃ ~ +50℃ Size 149mm×73mm×32mm (H×W×D) Weight 210g including batteries
Note:
* Standard Packing List
Ultrasonic Thickness Gauge × 1, Standard Probe × 1, Battery × 2, Couplant × 1, Carrying Case × 1, Operating Manual × 1
(Kindly Reminder: Battery and Couplant is Not Included if Shipped By Air.)
** Optional Probes
Function Comparison
Want more information on Portable maintenance-free steel pipe diameter measuring gauge? Feel free to contact us.
Model ATO-UM-1 ATO-UM-1D ATO-UM-2 ATO-UM-2D Operating Principle P-E (pulse-echo) P-E (pulse-echo), E-E (Echo-Echo) P-E (pulse-echo) P-E (pulse-echo), E-E (Echo-Echo) Measuring Range in Standard Mode 0.8mm-300mm, depending on material and probe Measuring Range in Thru Coating Mode N/A 3-20mm N/A 3-20mm Measuring Resolution 0.1mm, 0.001 inch 0.1mm, 0.001 inch 0.01mm, 0. inch 0.01mm, 0. inch Probe Compensation Line 1 built-in probe compensation line 1 built-in probe compensation line 7 built-in probe compensation line 7 built-in probe compensation line Data Logger Y Y Y YTips: Measurement Method of Ultrasound Thickness Gauge
1. Single-point measurement method
It means that the ultrasound thickness gauge is used to measure any point of the measured material with a probe, and the display value is the thickness value.
2. Two-point measurement method
The ultrasound thickness meter is used to make two measurement at the same point of the measured material with a probe. In the second measurement, the probe's split surface is 90 degrees, and the smaller value in the two measurements is the thickness value.
3. Multi-point measurement method
When the measurement value is unstable, takes a measuring point as the center and makes multiple measurements in a circle with a diameter of about 30 mm. The minimum value is the thickness value.